CS-8070 Fully automatic multicores wire cut and peel machine for big size 70sqm cables

CS-8070 industrial-grade 70mm² wire processing system delivers precision cutting and stripping for large power cables, combining robust construction with intelligent automation. Designed for demanding applications, it handles thick insulation and large conductors with micron-level accuracy while maintaining high throughput in continuous operation. The system’s smart controls automatically adjust parameters for perfect results across various cable types.

Description

CS-8070 wire stripping machine adopts ARM high-speed processor, combined with advanced motion control technology, independently developed a new generation of wire harness processing equipment with complete intellectual property rights. It adopts advanced human-machine interface and humanized design, and is very simple to operate.

Function & Features
1. Wide range of applications: 70 square wire stripping machine can usually handle different types of cables, including copper wire, aluminum wire and other metal wires, and is widely used in power, communication, new energy vehicles, construction and other fields. Suitable for cables with larger diameters, especially cables with larger cross-sections.
2. Automatic control: CA-8070 is equipped with PLC automatic control system, which is easy to operate. Different parameters can be set and adjusted through buttons, touch screens, etc. to ensure stable and efficient stripping process.
3. Precise stripping: Through precise tools and adjustment systems, it can achieve precise stripping of cables, avoid damage to the wires or metal inside the cables, and ensure the quality of stripping. The length and depth of stripping can be adjusted according to needs.
4. High efficiency: CS-8070 square wire stripping machine has high working efficiency and is suitable for mass production needs. Through the automated stripping process, a large number of cable processing can be completed quickly.
5. Adjustable tool: This model of wire stripping machine is equipped with an adjustable tool, which can adjust the stripping depth according to the outer diameter and insulation thickness of different cables, thereby ensuring the best stripping effect.
6. High operational safety: It is designed with safety protection devices such as protective covers, emergency stop switches, etc. to ensure the safety of the operator.
7. Multifunctional design: In addition to the basic stripping function, it can also provide additional functions such as cutting and marking, so that the equipment has more application scenarios.
8. Durability and stability: This issue uses durable materials and undergoes strict production processes to ensure long-term stable operation of the equipment and reduce the failure rate.
9. Adapt to different cable types: It is suitable for various types of cables, such as single-core, multi-core, flat cables, etc., and can meet a variety of needs.
16. High-precision stripping: The machine adopts a precise measurement system and stripping control, which can efficiently complete the stripping tasks of cables of various specifications, ensure the surface of the workpiece is neat, and avoid waste of materials.

Technical Data

Model CS-8070
Available Wire Size AWG7 – AWG1/0
Conductor Cross-Section 10-70mm²
Cutting Length 1-99999mm
Cutting Length Tolerances ≤(0.002*L) mm
Stripping Length Head 1-800mm;Tail 1-260mm
Conduit Diameter φ25mm
Production Rate 1000-1800pcs/h
Display Screen 7 inch touch screen
Wire Feed Method Belt feeding
Drive Method 32 wheels drive
Power Supply 220V/110V
Power 3500W
Weight 190kg
Dimensions 140*76*134cm

Additional information

Description

  1. Industrial Power Distribution Systems

  • Primary power feeders for heavy industrial equipment (100-250kW motors)

  • Main distribution busbars in manufacturing facilities

  • High-capacity machine tool power connections (large CNC systems, stamping presses)

  • Power supply for industrial electrolysis systems

 

  1. High-Current Electrical Installations

  • Main riser cables in skyscrapers and large commercial buildings

  • Substation connections (transformer-to-switchgear links)

  • Generator set output cables (500-1000kVA systems)

  • Welding machine main power cables (industrial spot/arc welders)

 

  1. Energy Infrastructure Applications

  • Wind turbine generator power collection systems

  • Solar farm combiner box to central inverter connections

  • Battery energy storage system (BESS) interconnections

  • Power plant auxiliary system wiring

 

  1. Specialized Heavy Equipment

  • Mining equipment power distribution (excavators, haul trucks)

  • Shipboard main power distribution (450V+ systems)

  • Offshore oil platform electrical systems

  • Large crane and hoist power feeds

 

  1. Transportation Electrification

  • Railway overhead catenary backup systems

  • Electric ferry charging station connections

  • Airport ground power units (GPU)

  • EV fast charging station backbone wiring (350kW+ chargers)

 

Technical Specifications:

  • Current Rating: 210-285A (depends on insulation and installation)

  • Voltage Rating: Typically 0.6/1kV (up to 3.6kV for some applications)

  • Common Conductor Types:

    • Class 2 stranded copper (most common)

    • Compact stranded aluminum (for weight-sensitive applications)

    • Tinned copper (marine/offshore use)

Insulation and Jacket Options:

  • XLPE (90°C dry/75°C wet operation)

  • EPR (flexible, high-temperature resistant)

  • LSZH (low smoke zero halogen for confined spaces)

  • Neoprene/PCP (oil/chemical resistant)

Installation Considerations:

  • Minimum bending radius: 10-12x cable diameter

  • Recommended pulling tension: ≤20N/mm²

  • Thermal expansion compensation required for long runs

  • Special termination techniques for aluminum conductors

Safety and Compliance:

  • Must use proper compression lugs (die size per conductor class)

  • Requires torque-controlled termination

  • Arc flash protection considerations

  • Complies with IEC 60502-2, BS 6622, NFPA 70 standards

Special Application Notes:

  1. For underground installations:

    • Requires direct burial rated construction

    • Must account for soil thermal resistivity

    • Needs protection against rodent damage

  2. In marine environments:

    • Must use tinned copper with marine-grade jacket

    • Requires additional UV protection for exposed runs

    • Needs special anti-vibration terminations

  3. For high-vibration areas:

    • Recommend extra-flexible stranding

    • Require vibration-resistant terminations

    • Need periodic torque checks on connections

Current-Carrying Capacity Examples:

  • Free air installation: ~285A (40°C ambient)

  • In conduit: ~245A (30°C ambient)

  • Underground: ~210A (20°C earth temperature)

Common Accessories:

  • Compression lugs (copper/aluminum)

  • Heat-shrink termination kits

  • Cable cleats and supports

  • Phase identification markers

Technical Data

If you wish to have the datasheet of this or other products, you can let us know here: CONTACT

Or email to sales@ksweijiang.com, we will send you the machine introduction.

Get Details & Price Now

If you hope to inquiry just this product, please send a message here. If you hope to inquiry several products, please Add To Quote, quote all products on the Request Quote page.

WEJION will send quotes back to you ASAP : )

Share on Facebok
Twitt this product
Pin this product
Email this product

Related Products